Testing Cold Storage with Rclone: a practical test plan
Before a service reads its files from the cloud via an Rclone mount, you should check more than directory access. This test plan covers cold reads, warm reads, write operations, cache behavior, file integrity, and failures.
An Rclone mount is quick to set up. The remote appears as a directory, ls shows files, and the first functional test has passed. That says little about production use.
As soon as a service accesses the mount, further questions arise: How long does the first access to a file take? Which accesses does the local cache serve? What happens to a file that has not yet been uploaded if Rclone crashes? Does a running container see the remounted mount again? And how does the service react when the cloud is temporarily unavailable?
This article provides a general test plan for this. You can use it for a document archive, media server, photo management system, or any other service that retrieves infrequently needed files from cold storage through Rclone.
The most important rclone options
For orientation, here are the Rclone options used in this test plan, translated in meaning from the documentation:
The complete lists are available in the Rclone documentation, particularly under rclone mount and in the overview of global flags.
First decide what you want to achieve
Cold storage does not automatically mean the same thing for every application. A media server generally reads large files sequentially. A photo management system loads many small preview files and jumps to different positions. A document archive opens comparatively small files, but often only once.
Before testing, note the key characteristics of your actual dataset:
- typical file size and largest file encountered
- number of files per directory
- full reads or random access to individual ranges
- ratio of read to write access
- number of concurrent users or processes
- changes made directly in the remote outside the mount
- acceptable wait time for a cold read
- maximum available space for the local cache
Only then can meaningful success criteria be defined. Opening a single file in 1.2 seconds may be perfectly acceptable for an archive and unusable for an interactive application.
Creating a reproducible test dataset
Rclone already includes a suitable tool for this. rclone test makefiles generates the same file tree every time with a fixed seed:
rclone test makefiles ./testdata \
--seed 42 \
--files 250 \
--files-per-directory 25 \
--min-file-size 16K \
--max-file-size 32M
Adjust the number and sizes to your actual dataset. Do not test only average files. A few very small files show how costly metadata access is; a few large files reveal throughput, read-ahead, and cache behavior.
Also add file names that could cause problems in practice:
mkdir -p "testdata/Sonderfälle/Unterordner"
printf 'Leerzeichen\n' > "testdata/Sonderfälle/Datei mit Leerzeichen.txt"
printf 'Umlaute\n' > "testdata/Sonderfälle/Grösse und Änderung.txt"
printf 'Grossschreibung\n' > "testdata/Sonderfälle/Test.txt"
printf 'Kleinschreibung\n' > "testdata/Sonderfälle/test.txt"
The final test is especially important if the local filesystem and cloud backend handle case sensitivity differently.
If your service accepts only certain formats, arbitrary binary files are not enough. In that case, also generate synthetic files in precisely those formats. For Paperless-ngx, these were PDFs with an actual text layer so the test would not inadvertently measure OCR performance instead of the storage path. For a photo management system, include different image sizes and formats in the dataset; for a media server, short files with different codecs.
A baseline measurement without a mount
Before FUSE and the VFS cache come into play, measure the backend directly. Copy the dataset to the test remote with Rclone and save a detailed log:
rclone copy ./testdata remote:cold-storage-test \
--progress \
--stats 5s \
--log-file rclone-copy.log \
--log-level INFO
Then verify that source and destination match:
rclone check ./testdata remote:cold-storage-test \
--one-way \
--download
--download is critical here because some backends do not provide suitable hashes. The comparison takes longer but provides a useful baseline for the later integrity test.
Record upload time, transfer rate, number of retries, and API errors. If direct access is already unstable, the mount cannot fix it.
Separating the test mount from the production cache
Use a separate mount point and separate cache directory for measurement:
rclone mount remote:cold-storage-test /mnt/rclone-test \
--vfs-cache-mode full \
--cache-dir /var/cache/rclone-test \
--vfs-cache-max-size 10G \
--vfs-cache-poll-interval 1m \
--allow-other \
--log-file /var/log/rclone-test.log \
--log-level INFO
The values are an example, not a general recommendation. Separation is what matters: an empty test cache makes cold reads reproducible without requiring you to delete files from an active production cache.
--vfs-cache-mode full is usually the most informative test mode for applications. Rclone buffers read and write access locally and can better emulate file access that would not be possible with pure object storage. This additional compatibility costs local disk space.
Always test from the actual service’s perspective
A mount may work for your user while still being unusable for the service. Common causes include a different user ID, missing --allow-other, container boundaries, or incorrect mount propagation.
Therefore, perform at least one complete read access using the same identity under which the application will later run:
sudo -u <service-user> sha256sum /mnt/rclone-test/pfad/zur/datei
If the service runs in Docker, the test belongs in the container:
docker exec --user <uid>:<gid> <app-container> \
sha256sum /pfad/im/container/datei
An actual application test is even better. Open the file through the service’s web interface or API. Only then will you notice whether the application, for example, starts multiple parallel reads, jumps to the end of the file, or expects additional metadata.
Measuring cold reads and warm reads separately
With --vfs-cache-mode full, there are three layers between the application and the cloud:
| Layer | What it contains |
|---|---|
| Remote | the complete file in the cloud service |
| VFS cache | locally stored portions of previously read files |
| Linux page cache | recently used data in RAM |
For a cold read, choose a file whose content has never been read through the test mount. In the directly subsequent warm read, it is in the VFS cache and usually also in RAM.
measure_read() {
file="$1"
label="$2"
start=$(date +%s%3N)
cat "$file" > /dev/null
end=$(date +%s%3N)
printf '%s: %s ms\n' "$label" "$((end - start))"
}
measure_read "/mnt/rclone-test/grosse-datei.bin" "Cold Read"
measure_read "/mnt/rclone-test/grosse-datei.bin" "Warm Read"
Do not measure only one file. Use at least ten previously unread files of different sizes and record the median, slowest value, and file size. A single best result is not a basis for a decision.
A warm read is not a pure disk test because the kernel can retain parts of the file in RAM. For most cold-storage scenarios, this is not a problem. What matters is what a user experiences when opening a file for the first time and again later. If you want to evaluate RAM and local disk separately, you must additionally control and demonstrably clear the page cache.
Do not test only complete reads
cat reads a file from beginning to end. Many applications behave differently:
- A video player initially reads headers and an index, later jumps to another position, and then continues reading sequentially.
- An image management system reads metadata and then generates a preview image.
- An archive program may read the end of the file first.
- Multiple workers may access different files simultaneously.
Test these workflows with the actual application. Monitor the Rclone log and cache in parallel. For large files, it is useful to see how much Rclone actually stores locally and whether --vfs-read-ahead matches the access pattern.
An Rclone mount is also not a sensible storage location for databases or other files that need reliable locking and frequent changes within the same file. The VFS layer compensates for differences between filesystems and object storage, but it does not turn the backend into a local filesystem.
Test the write path separately
If your service only reads, mount the remote read-only where possible. If it must write, test creating, overwriting, renaming, and deleting separately.
A written file does not necessarily appear in the remote immediately. With the VFS cache enabled, upload starts only after the file has been closed and --vfs-write-back has elapsed. Therefore, check both states:
- The application successfully closed the file.
- The file can then be read in the remote through direct Rclone access.
printf 'writeback-test\n' > /mnt/rclone-test/writeback-test.txt
# After --vfs-write-back has elapsed:
rclone cat remote:cold-storage-test/writeback-test.txt
Repeat the test with a large file and terminate Rclone while upload is still in progress. Then restart using the same cache directory and check whether the upload resumes. This exact time window determines how much data is at risk during a server failure.
Also test renaming and deletion. Many cloud backends implement these operations differently from a local filesystem. What matters is not only whether the command ends successfully, but when the change becomes visible through direct remote access and to other clients.
Testing changes outside the mount
Files may be changed through the vendor’s web interface, a second Rclone process, or another server. The mount does not always see these changes immediately because directory information is cached.
Therefore, use a second Rclone invocation to create a file directly in the remote:
printf 'external-change\n' > external-change.txt
rclone copyto external-change.txt \
remote:cold-storage-test/external-change.txt
Measure when the file appears in the mount. Repeat the test for modification and deletion. The result depends on the backend, its polling support, and --poll-interval and --dir-cache-time. If the application must see current changes immediately, this behavior must explicitly be included in the acceptance criteria.
With the Remote Control interface enabled, you can specifically discard the directory cache:
rclone rc vfs/forget
This is useful for a manual test but does not replace an appropriate operational strategy.
Putting the cache under pressure
An almost empty cache is the simplest case. In a second test round, deliberately set --vfs-cache-max-size to a small value and read more data than fits.
du -sh /var/cache/rclone-test/vfs
du -sh --apparent-size /var/cache/rclone-test/vfs
find /var/cache/rclone-test/vfs -type f | wc -l
The two sizes can differ greatly. In full mode, Rclone uses sparse files: a file shows its full logical size even though only the read portions use local space.
The cache limit is also soft. Rclone checks it on the schedule set by --vfs-cache-poll-interval, and open files cannot be removed. The cache may therefore temporarily exceed the limit. However, it should shrink again after files are closed and the next cleanup run occurs.
Record the peak value, the value after cleanup, and the time required. This lets you size the required local storage sensibly.
Simulating two different failures
An unreachable cloud and a crashed Rclone process are two different failures:
| Failure | What it tests |
|---|---|
| Backend or network unavailable, Rclone keeps running | Behavior during retries, timeouts, and access to already cached files |
| Rclone process terminated | FUSE mount behavior and recovery of the mount point |
Simulate both only in the test environment. You can forcefully terminate an Rclone container for the second case:
docker kill --signal KILL <rclone-container>
During the outage, check the application rather than only the mount point:
- Which functions remain available?
- How long does an access wait before an error appears?
- Are already fully cached files still accessible?
- Does the application stop new write operations?
- Is there an understandable error message, or only a hanging process?
- Does your monitoring trigger?
When the mount is absent, a write service must not silently write to the underlying local directory. Those files would be hidden when the mount returns. A simple safeguard before every write job is:
mountpoint -q /mnt/rclone-test || exit 1
After restarting Rclone, check the mount on the host and from every consuming container. A remounted mount reaches an already running container only with appropriate mount propagation. For Docker, rslave is usually required on the consuming side. Details are available in the article Operating Rclone mounts reliably in Docker.
A concrete example from Paperless-ngx
For my Paperless test, I generated 40 PDFs totaling 13.9 MB. A document that had not previously been opened took about 1.8 seconds, while a directly repeated access took 19 to 24 milliseconds. A VFS cache limited to 4 MB briefly rose to 12.7 MiB and was cleaned up again on the next run.
While the remote was unavailable, the document list, full-text search, and previews continued to work because that data was local. Only the original could not be opened. After remounting, the running Paperless container could access the files again without being restarted.
These figures are not a benchmark for Rclone or Proton Drive. The behavior is what matters: hot storage remained available locally, cold reads were slower but predictable, and the service recovered after the failure.
What belongs in the test log
A result that can be reviewed later includes at least:
- Rclone version and backend used
- operating system, FUSE variant, and filesystem of the cache directory
- complete mount command without credentials
- number, size distribution, and structure of test files
- cold-read and warm-read values for multiple files
- write duration until visibility in the remote
- cache peak value and cleanup duration
- result of
rclone check --download - behavior during backend failure and after the Rclone process is terminated
- recovery time from the application’s perspective
- retries, timeouts, throttling, and authentication errors from the log
Define a limit for each point in advance. Then the test ends with a decision rather than merely a collection of interesting numbers.
When the setup is ready
A cold-storage mount is ready for use if you can answer these questions with yes:
- Are cold reads fast enough for the intended service?
- Does the cache speed up repeated access as expected?
- Does local storage use remain manageable even under load?
- Do all files match after a complete download?
- Do all required file operations work with the selected backend?
- Does the application behave predictably during a cloud outage?
- Are write operations safely stopped when the mount is absent?
- Does a remounted mount reach all running consumers?
- Does monitoring show the outage before a user reports it?
If an answer is missing, you at least know exactly what you still need to work on. That is much more helpful than a mount that looked good at the first ls and only reveals its limitations in operation.
Change log
- October 25, 2026: Corrected: SIGKILL is already the default signal for docker kill; the —signal KILL option is for clarity only.
Comments
Comments are loaded from GitHub / Giscus.